¹«Á¦ ¹®¼­
 
¹«Á¦ ¹®¼­
 
 
1. Special products
2. Drying oven
3. Conveyor apparatus
4. Incubator
5. Constant temp. & humidity chamber
6. Water bath
7. Electric muffle furnace
8. Autoclave
9. Fume hood
10. Clean bench
11. Glove box
12. Shaker & Stirrer
13. Heating apparatus
14. Mills & Crusher
15. Analytical & measuring app.
16. Water purification apparatus
17. Freezing apparatus
18. Electronic balance
19. Evaporator
20. Vacuum pump
21. Washer & Ultrasonic cleaner
22. Microscope
23. Lab furniture & equipment
Analytical & measuring app. Home > Á¦Ç°¼Ò°³ > Analytical & measuring app. > pH meter
 
 
 
 
Á¦Ç°¸í :  pH meter
¸ðµ¨¸í :  HI-98230, HI-98240
 
                pHÃøÁ¤±â 

¡Ü  ÇöÀå¿¡¼­ µ¥ÀÌÅ͸¦ ±â·ÏÇÒ ¼ö ÀÖµµ·Ï ÇÁ¸°ÅÍ°¡ ÀåÂøµÇ¾î ÀÖ½À´Ï´Ù.


¡Ü  4¡­19.00pHÀÇ ³ÐÀº ÃøÁ¤¹üÀ§¸¦ °¡Áý´Ï´Ù.


¡Ü  ¾×Á¤È­¸éÀÌ Å©°í ³Ð¾î¼­ pH/ORP¿Í ¿Âµµ°¡ µÎÁÙ·Î µ¿½Ã¿¡ Ç¥½Ã µË´Ï´Ù.


Model

 HI 98230    

HI 98240

Range

pH

4.00 to 19.99 pH

-4.00 to 19.99 pH

mV

-

¡¾400.0 mV; ¡¾2000 mV

temperature

10.0 to 120.0¡ÆC /-14.0 to 248.0¡ÆF

10.0 to 120.0¡ÆC /-14.0 to 248.0¡ÆF

Resolution

pH

0.01 pH

0.01 pH

mV

-

0.1 mV(¡¾400 mV); 1 mV(outside)

temperature

0.1¡ÆC/0.1¡ÆF

0.1¡ÆC/0.1¡ÆF

Accuracy

pH

¡¾0.01 pH

¡¾0.01 pH

mV

-

¡¾0.5 mV(¡¾400 mV);¡¾2 m(outside)

temperature

¡¾0.5¡ÆC(0 to 70¡ÆC);¡¾1¡ÆC(outside);
¡¾1¡ÆF(32 to 158¡ÆF);¡¾1.8¡ÆF(outside)

¡¾0.5¡ÆC(0 to 70¡ÆC);¡¾1¡ÆC(outside);
¡¾1¡ÆF(32 to 158¡ÆF);¡¾1.8¡ÆF(outside)

pH calibration

Automatic, 1 or 2 point with 5 memorized buffer values
(pH 4.01, 6.86, 7.01, 9.18, 10.01)

Automatic, 1 or 2 point with 5 memorized buffer values
(pH 4.01, 6.86, 7.01, 9.18, 10.01)

mV calibration

-

Automatic, 2 point at 0, 350 mV or 0, 350, 1900 mV

Temperature compensation

Automatic, -10 to 120¡ÆC
(14 to 248¡ÆF)

Automatic, -10 to 120¡ÆC
(14 to 248¡ÆF)

pH electrode

HI 1618D smart electrode with temperature sensor,
DIN connector and 1 m(3.3') cable(included)

HI 1618D smart electrode with temperature sensor,
DIN connector and 1 m(3.3') cable(included)

PC connection

HI 9200/9 IR interface,
connector the computer RS232 serial port

HI 9200/9 IR interface,
connector the computer RS232 serial port

Logging interval

Selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes

Selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes

Printing interval

Selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes

Selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes

Power supply

4 x 1.5V AA/approx. 350 hours of continuous use
(with backlight OFF)
or 12 Vdc input

4 x 1.5V AA /approx. 350 hours of continuous use
(with backlight OFF)
or 12 Vdc input

Environment

0 to 50¡ÆC(32 to 122¡ÆF);RH max95%

0 to 50¡ÆC(32 to 122¡ÆF);RH max 95%

Dimensions

220 x 87 x 75 mm(8.7 x 3.4 x 2.9")

220 x 87 x 75 mm(8.7 x 3.4 x 2.9")

Weight

550 g(1.2 lb.)

550 g(1.2 lb.)

 
 
¹«Á¦ ¹®¼­