¹«Á¦ ¹®¼­
 
¹«Á¦ ¹®¼­
 
 
1. Special products
2. Drying oven
3. Conveyor apparatus
4. Incubator
5. Constant temp. & humidity chamber
6. Water bath
7. Electric muffle furnace
8. Autoclave
9. Fume hood
10. Clean bench
11. Glove box
12. Shaker & Stirrer
13. Heating apparatus
14. Mills & Crusher
15. Analytical & measuring app.
16. Water purification apparatus
17. Freezing apparatus
18. Electronic balance
19. Evaporator
20. Vacuum pump
21. Washer & Ultrasonic cleaner
22. Microscope
23. Lab furniture & equipment
Analytical & measuring app. Home > Á¦Ç°¼Ò°³ > Analytical & measuring app. > pH meter
 
 
 
 
Á¦Ç°¸í :  pH meter
¸ðµ¨¸í :  HI-122, HI-123
 
                pHÃøÁ¤±â 

¡Ü º¸±ÞÇü pH¸ÞŸ

HI 122¿Í HI 123Àº ÃֽŠ±â´Éµé°ú ÇÁ¸°ÅÍ ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.

0.001ÀÇ ÃÖ¼ÒÃøÁ¤ ´ÜÀ§¿Í ÀÚµ¿¿Âµµ º¸»ó±â´É ¿Ü¿¡µµ Àü±Ø º¸Á¤Æò°¡¿¡ ´ëÇÑ º¸Á¤ üũ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.

5Æ÷ÀÎÆ®( ¸ÂÃã°ª 2°³ Æ÷ÇÔÇÏ¿© 7°³)¿¡¼­ º¸Á¤À» ÇϱâÀ§ÇÑ ´É·ÂÀ» °¡Áø ÀÌ ¿É¼ÇµéÀÇ Á¶ÇÕÀº Áß¼º pH°ª°ú °­¾ËÄ®¸® pH°ª ¸ðµÎ¿¡ Àû¿ëÇϱ⿡ ÀûÀýÇÑ Á¦Ç°À¸·Î ¸¸µé¾î ÁÝ´Ï´Ù. µÎ ±â±â ¿ì¼ö¼º  ¿¬½À½ÇÇèÀ» ÇÏ°í °¢ RS232Æ÷Æ®¸¦ ÅëÇØ PC·Î ´Ù¿î·ÎµåÇϰųª Á÷Á¢ Ãâ·ÂÇϱâ À§ÇÑ °¢ º¸Á¤ÀÇ µ¥ÀÌÅÍ¿Í ÃøÁ¤À» ÀúÀåÇÒ ¼ö ÀÖ½À´Ï´Ù. HI 123Àº ppm´ÜÀ§·Î Á÷Á¢ ƯÁ¤ÀÌ¿ÂÀ» ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù. º¸Á¤Àº 5°³ÀÇ Ç¥Áظ޸𸮠¹öÆÛ·Î 1 ¶Ç´Â 2Æ÷ÀÎÆ®¿¡¼­ ºü¸£°í ½±½À´Ï´Ù.

¶ÇÇÑ, Callibration Check±â´ÉÀ¸·Î º¸Á¤ °á°ú°ªÀ» Àü±Ø »óÅÂ¿Í ¹ÝÀÀ¿¡ °üÇÑ Á¤º¸¸¦ ¾×Á¤¿¡¼­ ¹Ù·Î È®ÀÎÇÏ½Ç ¼ö ÀÖ½À´Ï´Ù.


Model

HI 122, HI 123

Range

pH

-2.00 to 16.00 pH; -2.000 to 16.000 pH

mV

¡¾999.9 mV; ¡¾2000 mV

selective ions

0.001 to 19999 ppm

temperature

-20.0 to 120.0¡ÆC

Resolution

pH

0.01 pH / 0.001 pH

mV

0.1 mV / 1 mV

selective ions

0.001 / 0.01 / 0.1 / 1 ppm

temperature

0.1¡ÆC

Accuracy pH

¡¾0.01 pH / ¡¾0.002 pH

mV

¡¾0.2 mV(¡¾699.9 mV)/¡¾0.5 mV(¡¾999.9 mV)
/¡¾1 mV (¡¾2000 mV)

selective ions

¡¾0.5% f.s.

temperature

¡¾0.4¡ÆC

BNC inputs

1 for pH electrode + 1 for ISE electrode

Calibration check

Status of electrode condition and response time
status of the buffer solutions during calibration

Relative mV offset range

¡¾2000 mV

pH calibration

Automatic, up to 5 points with 7 memorized values(1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers

ISE calibration

Automatic, 1 or 2 point with 5 memorized values(0.1, 1, 10, 100, 1000 ppm)

Temperature compensation

Automatic or manual, -20.0 to 120¡ÆC(-4 to 248¡ÆF)

pH electrode

HI 1131P, glass body, refillable,
BNC + pin connectors, 1 m cable(included)

Temperature probe

HI 7662-T with 1 m(3.3')cable(included)

Input impedance

1012

Log-on-demand

100 samples

Automatic data logging

2000 samples

PC connection

RS232 serial port, optoisolated

Printer

Built-in, with 44 mm plain paper

Power supply

12 VDC adapter(included)

Environment

0 to 50¡ÆC(32 to 122¡ÆF); RH max 95%

Dimensions

280 x 203 x 84 mm(11.0 x 8.0 x 3.3")

Weight

1.8 kg(4.0 lb.)

 
 